APC BK350 6 OUTLET BATTERY BACK-UPS CS

Product Code: APWBK350
Product Unit: Each
Stock is Available

  • Battery-protected and surge-only outlets.
  • Dataline Surge Protection.
  • Power conditioning.
  • Audible alarms.
  • Automatic restart of loads after UPS shutdown.
  • Automatic battery self-test.
  • LED status indicators.
  • Battery replacement without tools.
  • Transformer-block spaced outlets.
  • Resettable circuit breakers.

Product Details

General Information

Output power capacity 0.35 kVA
Output power 210 W
Input frequency 50/60 Hz
Surge energy rating 1020 J
Audible alarm(s) Yes
Typical backup time at full load 4.7 min
Typical backup time at half load 18.1 min
Battery recharge time 8 h
Hot-swap battery Yes
Product colour Beige
Cable length 1.8 m
LED indicators Yes
Operating temperature (T-T) 0 - 40 °C
Storage temperature (T-T) -15 - 45 °C
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%
Operating altitude 0 - 3000 m
Certification FCC Part 68/TUV
Safety UL/FCC/CE/C-Tick
Weight 5.98 kg
Package weight 6.36 kg
Products per pallet 80 pc(s)
Output connections 3 x NEMA 5-15R
Input connection type NEMA 5-15P
Dimensions (WxDxH) 91 x 284 x 165 mm
Nominal output voltage 120 V
Nominal input voltage 120 V
Package dimensions (WxDxH) 175 x 357 x 263 mm
Non-operating relative humidity (non-condensing) 0 - 95%
Weight (imperial) 5.67 kg (12.5 lbs)

Product Information

Brand APC
Type Specialty Batteries

Description

Data line surge protection Protects connected loads from surges, spikes, lightning, and other power disturbances. Battery-protected and surge-only outlets Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment LED status indicators Quickly understand unit and power status with visual indicators. Audible Alarms Provides notification of changing utility power and UPS conditions. Transformer-block spaced outlets Protect equipment with input transformer blocks without blocking access to other receptacles. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Battery replacement without tools Allows quick, easy battery replacement. Cold-start capable Provides temporary battery power when the utility power is out. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Resettable circuit breakers Enables a quick recovery from overload events. Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.

From the Manufacturer

Alternative Products

We are sorry but no alternatives are currently available.

Additional Documentation

product-pdf?productId=1113855&lang=en

Reviews

0 out of Five Stars 0/5 | 0 Reviews Login to Review this Product

No Reviews